Model | Image | Type | aaaaa |
Model TSA |
Transient/Surge Absorbers | Transient/Surge Absorbers (T/SA’s) provide system designers with a low cost, effective method of protecting sensitive electrical and electronic equipment from damage caused by switching transients, coil and motor backlash and near miss lightning strikes. There are 3 types available; single phase (1P), 3-phase DELTA 3- wire (3PD), and 3-phase WYE 4-wire (3PY). Each of these types are available in AC voltages of 120, 208, 240 and 480VAC. | |
Model 295 |
aaaa | aaaa | |
Model 410 |
Auto-Charged Capacitor Trip Device | The Model 410 Auto-Charged Capacitor Trip Device is a high speed capacitor-type circuit breaker tripping unit. It differs from the conventional capacitor trip device in that it has a self-contained standby power source, which is capable of maintaining full operating voltage for several days. | |
Model 412 |
Automatic Reverse Controller | The Model 412 Automatic Reverse Controller is a current sensor designed to detect jamming of sewage grinders, and to initiate the reversing of the grinder. This controller allows the selection of up to 5 forward/ reverse cycles, and provides for an alarm output if the number of cycles is exceeded. | |
Model 421 |
Over/Under Motor Load Monitor | The Model 421 Over/Under Motor Load Monitor detects an overload or underload condition on all types of running motors: conveyer motors, elevator motors, mixer motors, submersible pumps, etc. | |
Model 64-5 |
Power Factor Regulator | The Model 64-5 Power Factor Regulator is a monitoring and power factor control system. It is designed to help obtain an improved power factor, with a minimum of added capacitors. This device uses a unique phase-angle sensing circuit to monitor the power factor of a 3-phase power line. | |
Model 650 |
Loop Power Supply | The Model 650 Loop Power Supply provides DC power for instrumentation control modules. Each option provides three output selections as shown in the table below. For example the Model 650-240-24 has output options of 24VDC regulated, 32VDC unregulated, and 60Hz pulse at 46 peak volts. | |
Model 652 |
Loop Power Supply | The Model 652 Loop Power Supply provides DC power for instrumentation control modules. Each option provides three output selections as shown in the table below. For example the Model 652-120-12 has output options of 12VDC regulated, 16VDC unregulated, and 5VDC regulated. | |
Model 660 |
Trip Control | The Model 660 Trip Control, part of the 600 series line of instrumentation controls, is designed to monitor and maintain a set level on a measurable variable, such as liquid level, temperature, pressure, flow, etc. A user-provided 4-20ma current loop represents the measurable application. | |
Model 661 |
Alarm Control | The Model 661 Alarm Control, part of the 600 series line of instrumentation controls, is designed to monitor and maintain measurable applications such as liquid levels, temperature, pressure, flow, etc. A user-provided 4-20mA current loop represents the measurable application, and output connec- tions are provided for signal alarms. | |
Model 850 |
Two-Hand Control Module | The Model 850 Two Hand Control Module is designed to be used with two palm or pushbutton switches, which must be closed within 0.5 seconds of each other to operate machinery. As long as both switches are pressed, the relay will remain energized in the continuous mode. |