Ratings / Characteristics

Ratings

Rated load Non-inductive Inductive
Resistive load Lamp load Inductive load Inductive motor load
125 VAC 10A 10A 8A 8A
125 VAC 10A 10A 8A 8A

Note: 1. The non-inductive lamp load has an inrush current 10 times steady current.
2. The inductive load has a power factor of 0.4 minimum (AC).
3. The motor load has an inrush current 6 times steady current.
The above ratings were tested under the following conditions:
1. Ambient temperature:20±2°C
2. Ambient humidity:65±5%RH
3. Switching frequency:7 times/min

Characteristics

Permissible operating speed Mechanical: 20 operations/min max.
Electrical: 7 operations/min max.
Insulation resistance 100 MΩ min. (at 500 VDC with insulation tester)
Contact resistance 
(initial value)
100 MΩ min. (at 500 VDC with insulation tester)
Dielectric strength 2,000 VAC, 50/60 Hz, for 1 min between terminals of the same polarity
2,000 VAC, 50/60 Hz, for 1 min between terminals of the different polarity
4,000 VAC, 50/60 Hz, for 1 min between charged metal parts and the ground terminal
Vibration resistance Malfunction:10 to 55 Hz, 1.5-mm double amplitude
Shock resistance Malfunction: 300 m/s2
Destruction: 500 m/s2
Durability Mechanical: 50,000 operations min.
Electrical: 10,000 operations min.
Inrush current 100 A max. (8.3 ms max.)
Degree of protection IEC IP40
Ambient operating temperature –20 to +55°C (with no icing or condensation)
Ambient operating humidity 45 to 85%RH

Downloads

Document File Type File Size Download
A8L Series Datasheet PDF 602 KB