Ratings / Characteristics

Rating 5 A, 125 V (resistive load)
3 A, 250 V (resistive load)
Inrush current NC: 20 A max.
NO: 10 A max.
Contact resistance 50 mΩ max. (initial value)
Dielectric 
strength
Between terminals of same 
polarity
1,000 VAC, 50/60 Hz for 1 min
Between current-carrying metal part and
ground, and between each terminal and
non-current-car-rying metal part
1,500 VAC, 50/60 Hz for 1 min
Durability Mechanical 200,000 operations min.
Electrical 200,000 operations min.
Ambient operating temperature -25 to 80°C (with no icing or condensation)
Ambient operating humidity 45% to 85%RH
Degree of protection IP00
Electric shock protection class Class II
PTI (tracking characteristic) 175
Degree of contamination 
(application environment)
3 (IEC 947-5-1)

Note: The rated values are from testing conducted under the following conditions:
1) Ambient temperature: 20 ± 2°C
2) Ambient humidity: 65% ± 5%RH
3) Operating frequency: 20 operations/minute

Downloads

Document File Type File Size Download
A2A Series Datasheet PDF 280 KB