Ratings / Characteristics

Type Key-type Selector Switches
Allowable 
operating 
frequency
Mechanical 30 operations/minute max.
Electrical 30 operations/minute max.
Insulation resistance 100 MΩ min. (at 500 VDC)
Contact resistance 100 mΩ max. (intial value)
Dielectric 
strength
Between terminals of same 
polarity
2,500 VAC at 50/60 Hz for 1 min. (initial value)
Between each terminal and 
ground
2,500 VAC at 50/60 Hz for 1 min. (initial value)
Vibration 
resistanc
Malfunction 10 to 55 Hz, 1.5-mm double amplitude (malfunction within 1 ms)
Shock 
resistance
Malfunction 1000 m/s2 max. (malfunction within 1 ms)
Durability Mechanical 500,000 operations min. (Switches with 3 positions: 300,000 operations min.)
Electrical 500,000 operations min. (Switches with 3 positions: 300,000 operations min.) 
(250 VAC, 3 A, with an inductive load having power factor cos θ = 0.4)
Ambient operating temperature*1 -25 to 70°C
Ambient operating humidity 35% to 85% RH
Ambient storage temperature*1 -40 to 80°C
Degree of protection*2 Conforming to IP66
Electric shock protection class Class II
PTI (tracking characteristic) 175
Degree of contamination 
(application environment)
3 (EN 60947-5-1)
Weight Approx. 75 g (for 1NC/1NO)

*1. With no icing or condensation.
*2.Degree of protection from the front of the panel.

Downloads

Document File Type File Size Download
A30NK Series Datasheet PDF 65.1 MB