Ratings / Characteristics

Ratings

Rated voltage Resistive load
5 VDC 1 mA

Note: The ratings values apply under the following test conditions:
(1)Ambient temperature : 20±2ºC
(2)Ambient humidity: 65±5%
(3)Operating frequency: 20 operations/min

Characteristics

Permissible operating speed 1 mm to 300 mm/s
Permissible operating frequency Mechanical: 60 operations/min max. 
Electrical: 60 operations/min max.
Insulation resistance 100 MΩ min. (at 100 VDC)
Contact resistance (initial value) 3 Ω max.
Dielectric strength 100 VAC for 1 min between terminals of same polarity
Vibration resistance *1 Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
Shock resistance Destruction Destruction: 1000 m/s2 {approx. 100 G} max. 
Malfunction Malfunction*1: 300 m/s2 {approx. 30 G} max.
Durability *2 Mechanical Mechanical: 150,000 operations min. (20 operations/min.) 
Electrical Electrical: 100,000 operations min. (20 operations/min.)
Degree of protection IEC IP40
Ambient operating temperature -25ºC to +85ºC (at ambient humidity of 60 % max.) (with no icing or condensation)
Ambient operating humidity 85 % max.(for +5ºC to +35ºC)
Weight Approx. 0.02 g

Note: The data given above are initial values.
*1 The given values apply for Total Travel Position. Close or open circuit of the contact is 1ms max.
*2 For testing conditions, consult your OMRON sales representative.

Downloads

Document File Type File Size Download
D3SH Series Datasheet PDF 1.1 MB