Ratings / Characteristics

Ratings

Rated voltage Resistive load
30 VDC 0.1 A (resistive load)

Note: The ratings values apply under the following test conditions:
(1)Ambient temperature : 20±2ºC
(2)Ambient humidity: 65±5%
(3)Operating frequency: 30 operations/min

Characteristics

Permissible operating speed 1 mm to 500 mm/s
Permissible operating frequency Mechanical: 200 operations/min max. 
Electrical: 30 operations/min max.
Insulation resistance 100 MΩ min. (at 250 VDC)
Contact resistance (initial value) 50 mΩ max.
Dielectric strength 250 VAC, 50/60 Hz for 1 min between terminals of same polarity
250 VAC, 50/60 Hz for 1 min between current-carrying metal parts and ground
Vibration resistance *1 Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
Shock resistance Destruction 1,000 m/s2{approx. 100G} max.
Malfunction *1: 300 m/s2 {approx. 30G} max.
Durability *2 50,000 operations min.(30 operations/min)
Degree of protection IEC IP00
Degree of protection against electric shock Class Ⅲ
Proof tracking index (PTI) 175
Ambient operating temperature -20ºC to +80ºC (at ambient humidity of 60% max.)
(with no icing or condensation)
Ambient operating humidity 85% max. (for +5ºC to +35ºC)
Weight Approx. 0.3 g

Note: The data given above are initial values.
*1 The given values apply for Total Travel Position. Close or open circuit of the contact is 1ms max.
*2 For testing conditions, consult your OMRON sales representative.

Downloads

Document File Type File Size Download
D3C Series Datasheet PDF 438 KB