Characteristics

Characteristics

  Z-15 (except 
micro load and 
flexible rod)
Z-01H Z-15 
(flexible rod)
Z-10F Z-15H2
Operating speed 0.01 mm to 1 m/s *1 1 mm to 1 m/s 0.1 mm to 1 m/s *1 0.01 mm to 1 m/s
Operating 
frequency
Mechanical 240 operations/min 120 operations/min 240 operations/min 240 operations/min
Electrical 20 operations/min max
Insulation resistance 100 MΩ min. (at 500 VDC)
Contact resistance 15 mΩ max. 
(initial value)
50 mΩ max. 
(initial value)
15 mΩ max. 
(initial value)
25 mΩ max. 
(initial value)
15 mΩ max. 
(initial value)
Dielectric strength Between contacts of same polarity 
Contact gap G: 
1,000 VAC, 50/60 Hz for 1 min 
Contact gap H: 
600 VAC, 50/60 Hz for 1 min
Contact gap E: 
1,500 VAC, 50/60 Hz for 1 min
Between contacts of 
same polarity 
Contact gap G: 1,000 
VAC, 50/60 Hz for 1 min 
Contact gap H: 600 VAC, 
50/60 Hz for 1 min
Between contacts of 
same polarity 
Contact gap F: 1,500 
VAC, 50/60 Hz for 
1 min
Between contacts of 
same polarity 
600VAC, 50/60Hz for 
1 min
Between current-carrying metal parts and ground, and between each terminal and non-current-carrying metal parts 2,000 VAC, 50/60 Hz for 1 min
Vibration resistance Malfunction 10 to 55 Hz, 1.5-mm double 
amplitude * 5
10 to 20 Hz, 1.5-mm double 
amplitude *5
10 to 55 Hz, 1.5-mm double amplitude *5
Shock resistance Destruction 1,000 m/s2 max.
Malfunction 300 m/s2 max. *2 *5 50 m/s2 max. *5 300 m/s2 max. *3 *5 100 m/s2 max.
Durability Mechanical Contact gap G, H: 
20,000,000 operations min. 
Contact gap E: 300,000 operations
1,000,000 
operations min.
500,000 
operations min. *1
20,000,000 
operations min.
Electrical Contact gap G, H: 
500,000 operations min. 
Contact gap E: 
100,000 operations min.
100,000 
operations min.
100,000 
operations min.
500,000 
operations min.
Degree of protection General- 
purpose
IP00
Drip-proof Equivalent to IP62 (except terminals)
Degree of protection 
against electric shoc
k
Class I
Proof tracking index 
(PTI)
175
Ambient 
operating 
temperatur
General- 
purpose
- 25 °C to 80 °C (with no icing)
Drip-proof - 15 °C to 80 °C (with no icing)
Ambient 
operating 
humidity
General- 
purpose
35% to 85%RH
Drip-proof 35% to 95%RH
Weight Approx. 22 to 58 g Approx. 42 to 48 g Approx. 34 to 61 g Approx. 22 g

Note: *1. The values are for the plunger models. (For the lever models, the values are at the plunger section.) (Consult your 
       OMRON representative for other models.) 
*2. The values are for the Z-15G pin plunger. 
*3. The values are for the Z-10FY-B. 
*4. The values are for the pin plunger. The durability for models other than the pin plunger is 10,000,000 min. 
*5. Malfunction: 1 ms max.

Downloads

Document File Type File Size Download
Z Series Datasheet PDF 7.3 MB