Ratings / Characteristics

Ratings

Model Item Rated voltage Resistive Load
V-21 250VAC 21A
125VDC
250VDC
0.6A
0.3A

V-16

250VAC 16A
125VDC
250VDC
0.6A
0.3A
V-15 250VAC 15A
125VDC
250VDC
0.6A
0.3A
V-10 250VAC 10A
125VDC
250VDC
0.6A
0.3A
V-21(IN) DC30V 12 A

Note: The ratings values apply under the following test conditions:
Ambient temperature:20±2°C
Ambient humidity:65±5%
Operating frequency:30operations/min



Characteristics

Item V-10 V-15 V-16 V-21 V-21(IN)
Permissible operating speed 0.1mm to 1 m/s max. (pin plunger models)
Permissible operating frequency Mechanical 600 operations/min max. (pin plunger models)
Electrical 60 operations/minaaa
Insulation resistance 100MΩ min. (at 500 VDC with insulation tester)
Contact resistance (initial value) 15mΩ max.
Dielectric strength *1 Between terminals of
the same polarity
AC1,000V 50/60Hz 1min
Between currentcarrying
metal parts
and ground
AC1,500V 50/60Hz
1min
AC1,500V 50/60Hz
1min
AC2,000V 50/60Hz 1min
Between each terminals
and non-currentcarrying
metal parts
AC1,500V 50/60Hz
1min
AC1,500V 50/60Hz
1min
AC2,000V 50/60Hz 1min
Vibration resistance *2 Malfunction 10 to 55 Hz, 1.5-mm double amplitude
Shock resistance *2 Durability 1,000 m/s2 {approx. 100 G} max.
Malfunction 200 m/s2{approx. 20G} max. 300 m/s2 {approx. 30 G} max. 
Durability *3 Mechanical 50,000,000 operations min. (60 operations/min)
Electrical 300,000 operations min.
(30 operations/min)
Heat resistive: 50,000
operations min
(30 operations/min)
100,000 operations min.
(30 operations/min)
Heat resistive: 20,000
operations min
(30 operations/min)
100,000 operations min.
(30 operations/min)
Degree of protection IEC IP40
Degree of protection against electric shock Class I
Proof tracking index (PTI) 175
Ambient operating temperature -25 to 105°C
(Heat resistive: -25 to 150°C)
-25 to 105°C -25 to 80°C
-25 to 105°C (V-21 series: -25 to 80°C) (Heat resistive: -25 to 150°C) at ambient humidity of 60% max.
(with no icing or condensation)
Ambient operating humidity 85% max. (for 5 to 35°C)
Weight Approx. 6.2g (pin plunger models)

Note: The data given above are initial values.
*1. The dielectric strength shown in the table indicates a value for models with a Separator.
*2. For the pin plunger models, the above values apply for use at the free position and total travel position. For the lever models, they apply at the total travel position. Close or open circuit of the contact is shorter than 1 ms.
*3. For testing conditions, consult your OMRON sales representative.

Downloads

Document File Type File Size Download
V Series Datasheet PDF 2.3 MB