Ratings / Characteristics

Ratings

Model Item Rated voltage Resistive Load
D3V-21 250VAC 21A
125VDC 0.6A
250VDC 0.3A

D3V-16

250VAC 16A
125VDC 0.6A
250VDC 0.3A
D3V-11 250VAC 11A
125VDC 0.6A
250VDC 0.3A
D3V-6 250VAC 6A
125VDC
0.4A
250VDC 0.3A
D3V-01 DC30V 12 A

Note: 1. The above current values are the normal current values of models with a contact gap of 1 mm (gap F), which vary with the normal current values of models with a contact gap of 0.5 mm (gap G).
Note 2. The ratings values apply under the following test conditions:
Ambient temperature: 20±2°C
Ambient humidity:65±5%
Operating frequency: 30 operations/min



Characteristics

Item D3V-21 D3V-16 D3V-11 D3V-6 D3V-01
Permissible operating speed 0.1 mm to 1 m/s (pin plunger models)
Permissible operating frequency Mechanical 600 operations/min max.
Electrical 30 operations/min max.
Insulation resistance 100MΩ min. (at 500 VDC with insulation tester)
Contact resistance (initial value) 50 mΩ max. 30 mΩ max. 0.49N {50 gf}: 50 mΩ max.
0.25N {25 gf}: 100 mΩ max.
Dielectric strength
(see note 2)
1,000 VAC, 50/60 Hz for 1 min between terminals of the same polarity
2,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and ground, and between each terminal and noncurrent- carrying metal parts
Vibration resistance
(see note 3)
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
Shock resistance
(see note 3)
Durability 400 m/s2 {approx. 40 G} max.
Malfunction 100 m/s2 {approx. 10 G} max.
Durability
(see note 4)
Mechanical 10,000,000 operations min.
Electrical 50,000 operations min. 100,000 operations min. 200,000 operations min. 500,000 operations min.
Degree of protection IEC IP40
Degree of protection against electric shock Class I
Ambient operating temperature –25 to +85°C (at ambient humidity of 60% max.) (with no icing or condensation) –25 to +105°C (at ambient humidity of 60% max.) (with no icing or condensation) –25 to +85°C (at ambient humidity of 60% max.) (with no icing or condensation)
Ambient operating humidity 85% max. (for +5 to +35°C)
Weight Approx. 6.2g (pin plunger models)

Note 1. The data given above are initial values.
Note 2. The dielectric strength values shown in the table are for models with a Separator.
Note 3. For the pin plunger models, the above values apply for use at both the free position and total travel position. For the lever models, they apply at the total travel position.
Note 4. For testing conditions, contact your OMRON sales representative.

Downloads

Document File Type File Size Download
D3C Series Datasheet PDF 2.4 MB