Ratings / Characteristics

Ratings

Model Item Rated voltage Resistive Load
D2VW-5 250VAC
125VDC
5A
5A
30VDC 5A

D2VW-01

125VAC 0.1A
30VDC 0.1A

Note: The ratings values apply under the following test conditions:
Ambient temperature: 20 ± 2ºC
Ambient humidity: 65 ± 5%
Operating frequency: 30 operations/min



Characteristics

Permissible operating speed 0.1mm to 1 m/s max. (pin plunger models)
Permissible operating frequency Mechanical 300 operations/min max.
Electrical 30 operations/min max.
Insulation resistance 100 MΩ min. (at 500 VDC)
Contact resistance (initial value) 50 mΩ max. (100 mΩ max. for molded lead wire models)
Dielectric strength *1 1,000 VAC, 50/60 Hz for 1 min between terminals of same polarity
1,500 VAC, 50/60 Hz for 1 min between current-carrying metal parts and ground 
1,500 VAC, 50/60 Hz for 1 min between each terminal and non-current-carrying metal parts
Vibration resistance *2 Malfunction 10 to 55 Hz, 1.5-mm double amplitude
Shock resistance *2 Destruction 1,000m/s2{approx. 100G} max.
Malfunction *2: 300 m/s2{approx. 30G} max.
Durability *3 Mechanical 10,000,000 operations min.(60 operations/min)
Electrical D2VW-5 models:100,000 operations min(30operations/min)
D2VW-01 models:1,000,000 operations min(30 operations/min)
Degree of protection IEC IP67(excluding the terminals on terminal models)
Degree of protection against electric shock Class I
Proof tracking index (PTI) 175
Ambient operating temperature -40ºC to +85 ºC (at ambient humidity of 60% max.)
(with no icing or condensation)
Ambient operating humidity 95% max. (for +5ºC to +35ºC)
Weight Approx. 7 g (pin plunger models with terminals)

Note: The data given above are initial values.
*1 The dielectric strength shown in the table indicates the value for models with a Separator (refer to "Basic Switch Common Accessories").
*2 For the pin plunger models, the above values apply for use at the free position and total travel position. For the lever models, they apply at the total travel position. Close or open circuit of the contact is 1 ms max.
*3 For testing conditions, consult your OMRON sales representative.

Downloads

Document File Type File Size Download
D2VW Series Datasheet PDF 1.2 MB