Ratings / Characteristics

Ratings

Model Item Rated voltage Resistive Load
D2S-10 250VAC 10.1A
D2S-5 125VAC
250VAC
5A
3A

D2S-01

125VAC 0.1A
30VDC 0.1A

Note: The ratings values apply under the following test conditions:
Ambient temperature: 20±2ºC
Ambient humidity: 65±5%
Operating frequency: 30 operations/min.



Characteristics

Permissible operating speed 0.1 mm to 1 m/s (pin plunger models)
Permissible operating frequency Mechanical 400 operations/min max.
Electrical 30 operations/min max.
Insulation resistance 100 MΩmin. (at 500 VDC)
Contact resistance (initial value)
OF 1.47 N {150 gf}: D2S-10, D2S-5 models:
D2S-01 models:
30 mΩ max.
50 mΩ max.
OF 0.49 N {50 gf}: D2S-5 models:
D2S-01 models: 
50 mΩ max. 
100 mΩ max.
Dielectric strength *1 1,000 VAC, 50/60 Hz for 1 min between terminals of same polarity
1,500 VAC, 50/60 Hz for 1 min between current-carrying metal parts and ground
1,500 VAC, 50/60 Hz for 1 min between each terminal and non-current-carrying metal parts
Vibration resistance *1 Malfunction 10 to 55 Hz, 1.5-mm double amplitude
Shock resistance Destruction
OF 1.47 N {150 gf}:
OF 0.49 N {50 gf}:
1,000 m/s2 {approx. 100G} max. 
500 m/s2 {approx. 50G} max.
Malfunction *2
OF 1.47 N {150 gf}: 
OF 0.49 N {50 gf}:
300 m/s2 {approx. 30G} max. 
200 m/s2 {approx. 20G} max.
Durability *3 Mechanical D2S-10 models:10,000,000 operations min.(60 operations/min)
D2S-5,D2S-01 models:30,000,000 operations min.(60 operations/min)
Electrical D2S-10 modeis:50,000 operations min.(30 operations/min)
D2S-5,D2S-01 models:200,000 operations min.
(30 operations/min)
Degree of protection IEC IP40
Degree of protection against electric shock Class I
Proof tracking index (PTI) 175
Ambient operating temperature -25ºC to +80ºC (at ambient humidity of 60% max.) 
(with no icing or condensation)
Ambient operating humidity 85% max. (for +5ºC to +35ºC)
Weight Approx. 1.6 g (pin plunger models)

Note: The data given above are initial values.
*1 The values for dielectric strength shown are for models with a Separator (refer to "Micro Switch Common Accessories").
*2 The values are at Free Position and Total Travel Position values for pin plunger, and Total Travel Position value for lever. Close or open circuit of the contact is 1ms max.
*3 For testing conditions, consult your OMRON sales representative.

Downloads

Document File Type File Size Download
D2S Series Datasheet PDF 618 KB