Ratings / Characteristics

Ratings

Model Rated voltage Resistive Load
D2SW-P2 30 VDC 2 A
250 VAC

D2SW-P01

30 VDC 0.1 A
125 VAC

Note: The ratings values apply under the following test conditions:
Ambient temperature: 20±2ºC
Ambient humidity: 65±5%
Operating frequency: 20 operations/min.



Characteristics

Item D2SW-P2 D2SW-P01
Permissible operating speed 0.1 mm to 500 mm/s (pin plunger models)
Permissible operating frequency Mechanical 120 operations/min max.
Electrical 20 operations/min max.
Insulation resistance 100 mΩ min. (500 VDC with insulation tester)
Contact resistance (initial value) Terminal models:50 mΩ max.
Molded lead wire models:100 mΩ max.
Terminal models:100 mΩ max.
Molded lead wire models:150 mΩ max.
Dielectric strength *1 1,000 VAC, 50/60 Hz for 1 min between terminals of the same polarities 600 VAC, 50/60 Hz for 1 min between terminals of the same polarities
1,500 VAC, 50/60 Hz for 1 min between current-carrying metal parts and ground, and between each terminal and non-current-carrying metal parts
Vibration resistance *2 Malfunction 10 to 55 Hz, 1.5-mm double amplitude
Shock resistance Durability 1,000 m/s2 {approx. 100G} max.
Malfunction *2: 300 m/s2 {approx. 30G} max.
Durability *3 Mechanical 1,000,000 operations min.
(60 operations/min.)
1,000,000 operations min.
(60 operations/min.)
Electrical 50,000 operations min.
(20 operations min.)
200,000 operations min.
(20 operations min.)
Degree of protection IEC IP67 (See note 5)
(excluding the terminals on terminal models)
Degree of protection against electric shock Class I
Proof tracking index (PTI) 175
Ambient operating temperature -20ºC to +70ºC (at ambient humidity of 60% max.)
(with no icing or condensation)
Ambient operating humidity 85% max. (for +5ºC to +35ºC)
Weight Approx.2 g (pin plunger models with terminals)

Note: The data given above are initial values.
*1 The dielectric strength shown in the table indicates values for models with a Separator.
*2 The values are at Free Position and Total Travel Position values for pin plunger, and Total Travel Position value for lever. Close or open circuit of contact is 1 ms max.
*3 For testing conditions, consult your OMRON sales representative.

Downloads

Document File Type File Size Download
D2SW-P Series Datasheet PDF 675 KB