Ratings / Characteristics

Ratings

Rated voltage D2F models D2F-01 models D2F-5 models
D2F models 1.47N (General-purpose) 0.74N (Low Operating Force) 1.47N (General-purpose) 0.74N (Low Operating Force) 1.47N (General-purpose)
Resistive Load  
125 VAC 3A 1A - -
30 VDC 2A 0.5A 0.1A -
250 VAC - - 5A

Note: The ratings values apply under the following test conditions:
Ambient temperature: 20±2ºC
Ambient humidity: 65±5%
Operating frequency: 30 operations/min.



Characteristics

  D2F-01 models D2F models D2F-5 models
0.74 N (Low operating force) 1.47 N (General-purpose) 1.47 N (General-purpose)
Permissible operating speed Pin plunger models: 1 mm to 500 mm/s,
Lever models: 5 mm to 500 mm/s
Permissible operating frequency Mechanical Pin plunger models: 200 operations/min,
Lever models: 100 operations/min
Mechanical 30 operations/min
Insulation resistance 100 MΩ min. (at 500 VDC with insulation tester)
Contact resistance (initial value) 100 mΩ max. 50 mΩ max. 30 mΩ max.
Dielectric strength Between terminals of the same
polarity
600 VAC 50/60 Hz 1min
Between current-carrying metal
parts and ground
1,500 VAC 50/60 Hz for 1 min
Between each terminals and
non-current-carrying metal parts
1,500 VAC 50/60 Hz for 1 min
Vibration resistance *1 Malfunction 10 to 55 Hz, 1.5 mm double amplitude
Shock resistance Durability 1,000 m/s2 {approx. 100G} max.
Malfunction 300 m/s2 {approx. 30G} max.
Durability Mechanical 1,000,000 operations min. (60 operations/min)/td>
Electrical 100,000 operations min.
(30 operations/min)
30,000 operations min.
(30 operations/min)
10,000 operations min.
(30 operations/min)
Degree of protection IEC IP40
Ambient operating temperature –40 to +85 °C(at ambient humidity of 60% max.)
(with no icing or condensation)
Ambient operating humidity 85% max. (for +5°C to +35°C)
Weight Approx. 0.5 g (pin plunger models)

Note: The data given above are initial values.
*1.  The values are at Free Position and Total Travel Position values for pin plunger, and Total Travel Position value for lever. Close or open circuit of the contact is 1ms max.
*2.  For testing conditions, consult your OMRON sales representative.

Downloads

Document File Type File Size Download
D2F Series Datasheet PDF 851 KB