Ratings / Characteristics

Ratings

Item Rated voltage D2FD-2 models D2FD-01 models
Resistive Load
125 VAC 2A 0.1 A
30 VDC 2A 0.1 A

Note: The ratings values apply under the following test conditions:
Ambient temperature: 20±2ºC
Ambient humidity: 65±5%
Operating frequency: 20 operations/min.



Characteristics

  D2FD-2 models D2FD-01 models
Permissible operating speed 1 mm to 500 mm/s
Permissible operating frequency Mechanical 120 operations/min
Electrical 20 operations/min max
Insulation resistance 100 MΩ min. (at 500 VDC)
Contact resistance (initial value) 30 mΩ max. 100 mΩ max.
Dielectric strength (see note 2) Between terminals of the same
polarity
600 VAC 50/60 Hz 1 min
Between current-carrying metal
parts and ground
1,500 VAC 50/60 Hz for 1 min
Between each terminals and
non-current-carrying metal parts
1,500 VAC 50/60 Hz for 1 min
Vibration resistance  (see note 3) Malfunction 10 to 55 Hz, 1.5 mm double amplitude
Shock resistance  (see note 3) Destruction 1,000 m/s2 {approx. 100G} max.
Malfunction 300 m/s2 {approx. 30G} max.
Durability  (see note 4) Mechanical 300,000 operations min. (at 60 ops./min.)
Electrical 30,000 operations min. (at 20 ops./min.) 100,000 operations min. (at 20 ops./min.)
Degree of protection IP6X
Ambient operating temperature −20 to +70°C (at 60%RH max.) (with no icing)
Ambient operating humidity 85%RH max. (for +5 to +35°C)
Weight Approx. 0.7 g (pin plunger, PCB terminal models)

Note: 1. The data given above are initial values.
2. The dielectric strength shown in the table indicates a value for models with a Separator.
3. For the pin plunger models, the above values apply for both the free position and total travel position. For the lever models, the values apply at the total travel position. Contact opening or closing time is within 1 ms.
4. Consult your OMRON sales representative for testing conditions.

Downloads

Document File Type File Size Download
D2FD Series Datasheet PDF 354 KB