Ratings / Characteristics

Ratings

Item Rated voltage Resistive Load
12 VDC 0.1A

Note: The ratings values apply under the following test conditions:
Ambient temperature: 20±2ºC
Ambient humidity: 65±5%
Operating frequency: 20 operations/min.



Characteristics

Permissible operating speed 30 mm to 500 mm/s (pin plunger models)
Permissible operating frequency Mechanical 30 operations/min max.
Electrical 20 operations/min max
Insulation resistance 100 MΩ min. (at 500 VDC)
Contact resistance (initial value) Terminals 100 mΩ max.
Molded lead wire
models
150 mΩ max.
Dielectric strength Between terminals of the same
polarity
600 VAC 50/60 Hz 1min
Between current-carrying metal
parts and ground
1,500 VAC 50/60 Hz for 1 min
Between each terminals and
non-current-carrying metal parts
1,500 VAC 50/60 Hz for 1 min
Vibration resistance *1 Malfunction 10 to 55 Hz, 1.5 mm double amplitude
Shock resistance *1 Durability 1,000 m/s2 max.
Malfunction 300 m/s2 max.
Durability *2 Mechanical 200,000 operations min. (30 operations/min)
Electrical 200,000 operations min. (20 operations/min)
Degree of protection IEC IP67
Ambient operating temperature -40 to 85°C (at 60%RH max.) (with no icing or condesenation)
Ambient operating humidity 95% max. (for +5 to +35°C)
Weight Approx. 0.7 g (for pin plunger models with terminals)

Note: The data given above are initial values.
1. For the pin plunger models, the above values apply for use at the free position, operating position, and total travel position. For the lever models, they apply at the total travel position. Close or open circuit of the contact is 1ms max.
2. For testing conditions, consult your OMRON sales representative.

Downloads

Document File Type File Size Download
D2AW Series Datasheet PDF 2.0 MB