Ordering Information

Classification Terminal form Contact
structure
Protective structure Rated coil Type Characteristics
Voltage (V) Resistance (Ω)
Single PCB terminal SPDT
(1c)
Simple plastic seal DC12 225 G8NB-1 Standard
180 G8NB-1S Low operating voltage
130 G8NB-1U Super low operating voltage
Flux protection (Open vent hole) 225 G8NB-17R Standard
180 G8NB-17SR Low operating voltage
130 G8NB-17UR Super low operating voltage
Twin SPDT × 2
(1c×2)
Simple plastic seal 225 G8NB-2 Standard
180 G8NB-2S Low operating voltage
130 G8NB-2U Super low operating voltage
Flux protection (Open vent hole) 225 G8NB-27R Standard
180 G8NB-27SR Low operating voltage
130 G8NB-27UR Super low operating voltage

Ratings / Characteristics

Operation coil

Rated voltage(V) Coil resistance
(Ω)
Rated current
(mA)
Operating
voltage
(V)
Release
voltage
(V)
Max. of applied voltage
(5A conduct, 105ΩC)
(V)
Service voltage
range
(V)
Rated power
consumption
(mW)
DC 12 225 53.3 7.2 or less 1.0 or more DC16, continuous DC10 to 16 640
DC16, 15 min. 800
180 66.7 6.5 or less DC14, continuous
130 92.3 5.5 or less 0.8 or more DC16, 3 min. 1108


Switching area

Item Performance
Contact material Silver alloy
Rated voltage DC12V
Rated load Motor load, 25A
Inrush current 30A
Continuous carry current*1 5A
Allowable carrying current 30A at DC14V( 30min.)*2 (Reference)
Min. Carry / Switching Current DC12V 1A


Performance

Item Standard value
Contact resistance*3 50mΩ or less
Operating time*4 10ms or less
Release time*4 5ms or less
Insulation resistance*5 Between coil and terminal 100MΩ or more
Between homopolar contacts 100MΩ or more
Withstand voltage*6 Between coil and terminal AC500V for 1min.
Between homopolar contacts AC500V for 1min.
Vibration
resistance
Durability 33Hz 45m/s2
Malfunction (Detecting time:1ms) 10 to 400Hz 45m/s2
Shock resistance Durability 1000m/s2 (Operating time:6ms)
Malfunction (Detecting time:1ms) 100m/s2 (Operating time:11ms)
Mechanical endurance (Switching frequency:18,000 times/h) 1,000,000 times
Electrical endurance (Rated load) 100,000 times
Ambient temperature -40 to 105°C
Ambient humidity 35 to 85%RH
Weight 4g

Note: All values above are measured in early time under an ambient temperature of +20°C and humidity of 65% unless stated.
*1. The value stated is at maximum temperature in a guaranteed ambient temperature.
*2. This is an acceptable current-carrying value in abnormal, and this is not a value which guarantee a repeat current-carrying.
Please check under actual use condition before use.
*3. Measured with a voltage drop method at DC5V 1A.
*4. It changes depend on how the rated voltage is operated, but bounce-time is not included.
*5. Measured at DC500V.
*6. Measured under 1mA of leak current, 50/60Hz for 1minute.

Downloads

Document File Type File Size Download
G6NB Series Datasheet PDF 461 KB