Ordering Information

Classification Terminal form Contact
structure
Protective structure Rated coil Type Characteristics
Voltage (V) Resistance (Ω)
Micro ISO Plug-in ISO terminal SPST
(1a)
Unsealed
(In a case)
DC24 315.1 G8HN-1A2T-RJ Standard
DC12 95.9
124.2 G8HN-1A2T-RH High-current
Simple
plastic seal
DC24 315.1 G8HN-1A4T-RJ Standard
DC12 95.9
124.2 G8HN-1A4T-RH High-current
SPDT
(1c)
Unsealed
(In a case)
DC24 315.1 G8HN-1C2T-RJ Standard
DC12 95.9
124.2 G8HN-1C2T-RH High-current
Simple
plastic seal
DC24 315.1 G8HN-1C4T-RJ Standard
DC12 95.9
124.2 G8HN-1C4T-RH High-current

Ratings / Characteristics

Operation coil

Rated voltage(V) Coil resistance(Ω) Rated current
(mA)
Operating
voltage
(V)
Release
voltage
(V)
Service voltage
range
(V)
Rated power
consumption
(mW)
Between terminals (Surge
suppression)
DC 12 95.9 (1.1k, 1/4W) 125 8.0 or less 1.2 or more DC10 to 16 1502
124.2 97 8.0 or less 1.2 or more DC10 to 16 1159
315.1 (4.3k, 1/4W) 76 16.0 or less 2.4 or more DC20 to 32 1828


Switching area

Item Performance
Contact material Silver alloy
Kinds Standard High-current
Rated voltage DC12V DC24V DC12V
Rated load N.O. side Resistance load, 20A Resistance load, 10A Resistance load, 35A
N.O. side Resistance load, 10A Resistance load, 5A Resistance load, 20A
Inrush current N.O. side 100A 50A 120A
N.C. side 60A 30A 60A
Continuous carry current*1 N.C. side 20A 10A 35A
N.C. side 10A 5A 20A
Min. Carry / Switching Current DC12V 1A


Performance

Item Standard Value
Standard High-current
DC12V DC24V DC12V
Voltage drop between terminals N.O. side 200mV or less, 20A 200 mV or less, 10A 200 mV or less, 35A
N.C. side 200 mV or less, 10A 200 mV or less, 5A 200 mV or less, 20A
Operating time*3 10ms or less
Release time*2 10ms or less
Insulation resistance*3 Between coil and terminal 10MΩ or more
Between homopolar contacts 10MΩ or more
Withstand voltage*4 Between coil and terminal AC500V for 1min.
Between homopolar contacts AC500V for 1min.
Vibration
resistance
Durability 33Hz 43.1m/s2
Malfunction (Detecting time:1ms) 20 to 500Hz 43.1m/s2
Shock resistance Durability 1000m/s2 (Operating time:6ms)
Malfunction (Detecting time:1ms) 100m/s2 (Operating time:11ms)
Mechanical endurance (Switching frequency:18,000 times/h) 1,000,000 times
Electrical endurance (Rated load) 100,000 times
Ambient temperature -40 to 100°C
Ambient humidity 35 to 85%RH
Weight Approx. 20.0 g

Note: All values above are measured in early time under an ambient temperature of +20°C and humidity of 65% unless stated.
*1. The value stated is at maximum temperature in a guaranteed ambient temperature.
*2. It changes depend on how the rated voltage is operated, but bounce-time is not included.
*3. Measured at DC500V.
*4. Measured under 1mA of leak current, 50/60Hz for 1minute.

Downloads

Document File Type File Size Download
G8HN Series Datasheet PDF 214 KB