Ordering Information

Classification Terminal form Contact
structure
Protective structure Rated coil Type
Voltage (V) Resistance (Ω)
Micro ISO For PCB SPST
(1a)
Simple plastic seal DC12 135 G8HL-1A4P
For Plug-in ISO 150 G8HL-1A4T-R

Ratings / Characteristics

Operation coil

Rated voltage(V) Terminal form(Ω) Rated current
(mA)
Operating
voltage
(V)
Release
voltage
(V)
Max. of applied voltage
(20A conduct, 100ΩC)
(V)
Service voltage
range
(V)
Rated power
consumption
(mW)
  (Surge
suppression)
DC 12 135 - 90 7.0 or less 0.7 or more DC16, continuous DC10 to 16 1067
150 (1.1k,1/4W) 80 8.0 or less 0.7 or more 960


Switching area

Item Performance
Contact material Silver alloy
Rated voltage DC12V
Rated load Resistance load, 20A
Inrush current 100A
Continuous carry current*1 20A*1
Allowable carrying current 30A at DC14V( 30min.)*2 (Reference)
Min. Carry / Switching Current DC12V 1A


Performance

Item Standard value
G8HL-1A4P G8HL-1A4T-R
Voltage drop between terminals 200mV or less, 20A
Operating time*3 10ms or less 10ms or less
Release time*3 10ms or less 10ms or less
Insulation resistance*4 Between coil and terminal 10MΩ or more
Between homopolar contacts 10MΩ or more
Withstand voltage*5 Between coil and terminal AC500V for 1min.
Between homopolar contacts AC500V for 1min.
Vibration
resistance
Durability 33Hz 43.1m/s2
Malfunction (Detecting time:1ms) 20 to 500Hz 43.1m/s2
Shock resistance Durability 1000m/s2 (Operating time:6ms)
Malfunction (Detecting time:1ms) 100m/s2 (Operating time:11ms)
Mechanical endurance (Switching frequency:18,000 times/h) 1,000,000 times
Electrical endurance (Rated load) 100,000 times
Ambient temperature -40 to 100°C
Ambient humidity 35 to 85%RH
Weight 13g 14g

Note: All values above are measured in early time under an ambient temperature of +20°C and humidity of 65% unless stated.
*1. The value stated is at maximum temperature in a guaranteed ambient temperature.
*2. This is an acceptable current-carrying value in abnormal, and this is not a value which guarantee a repeat current-carrying.
Please check under actual use condition before use.
*3. It changes depend on how the rated voltage is operated, but bounce-time is not included.
*4. Measured at DC500V.
*5. Measured under 1mA of leak current, 50/60Hz for 1minute.

Downloads