Specifications

Input Voltage (V) 230 Vac
Input Load Range (hp) 1/3 - 1
Output Form SPST
Weight (kg) 0 Kg (kilogram)
Overcurrent Trip Class 125% of calibration point
Input AC Line Frequency (Hz) 50 / 60 (50 will increase all delay timers by 20%)
Maximum Input Power (W) 5
Output Load Rating (VA) 1 hp @ 240 Vac (17 A max.)
Overvoltage Trip Voltage (%) 265 Vac
Rapid Cycle Timer (s) 4 restarts allowed in 60 s period
Restart Delay Range Over/Under Voltage: 2 s; All other faults: Manual; 2 - 225 m
Trip Delay Range Overcurrent: 5 s; Dry-well: 4 s
Underload (%) Adjustable (70 to 90% of calibrated run power)
Undervoltage Reset Voltage (%) 190 Vac
Mounting Method Inside a Franklin™; Pente®; or CentriPro™ control box
Operating Temperature Max (°C) 55
Operating Temperature Maximum Fahrenheit 131
Operating Temperature Minimum Celsius -40
Operating Temperature Minimum Fahrenheit -40