Type Function Industries
Timers Delay On Make, Delay On Break, On/Off Cycling, Interval, Single Shot, Repeat Cycle, Flasher, Configurable Controller HVAC, Transportation, Railroad, General Machinery, Military, Elevator-Escalator, Lighting, Medical-Dental, Educational Institutions, Agriculture

Specifications

Adjustable Timing Ranges 9 timing ranges from 0.1 seconds to 10,000 hours, custom ranges also available
Output Rating Solid state switch rated for 10mA to 1A inductive with inrush current to 25 A for 8 mS.
Operating Temperature -20°C to +85°C
Timing Accuracy Better than ±2% at room temp, less than ±5% over operating temperature range
Terminations 1/4" male Quick Connect
Construction Circuitry encapsulated in thermoplastic housing
Operating Voltage DC: 12V, 24V, 36V, 48V, and 72V. AC: 24V, 115V, 230V 50/60 Hz.

Documents and Downloads

Document File Type File Size Download
Model No. FT01S Datesheet PDF 63 KB