The Amperite DFA series adjustable recycling timers provide a continuously operating off/on cycle as long as power is applied to the input terminals. Two knob operated potentiometers provide user adjustment of both the flash rate and duty cycle. One knob sets the Off time; the other sets the On time. Standard models allow both the Off time and On time to be adjusted over a 100:1 range. Custom timing is available.
Off/On recycling (flasher) timer. The initial timing period, after application of power, is "off". An option allows the unit to cycle "on" upon application of power. Standard timing ranges (Off and On time) are as follows: A: 0.1 second to 10 seconds / B: 0.25 second to 25 seconds / C: 0.6 second to 60 seconds / D: 1.2 second to 120 seconds / E: 1.8 second to 180 seconds / F: 1 minute to 100 minutes / G:1-4hours / H: 14.4 minutes to 24 hours / I: .6 minutes to 60 minutes / J: .1 minute to 10 minutes / K: 10 minutes to 24 hours / M:1-10hours